A redispatch activation record gives the change in active power that a grid operator requested for one accounting point and one interval. List Activations returns these records with product set to redispatch.

Power and direction

power_mw gives the magnitude of the requested change in active power. regulation_direction tells you how to read it. For example, power_mw of 2.5 with regulation_direction set to down means the grid operator requested 2.5 MW less net injection: less production or more consumption.

Which record to use

For each call, accounting point and interval, use the record with in_force set to true, if there is one. Two redispatch calls can both be in force for the same accounting point and interval, even in the same regulation direction. Use call_id to distinguish them. See Value in force.

The change in active power that a grid operator requests for one accounting point and one interval in a redispatch notification.

accounting_point_id
string<uuid>
required
call_id
string
required

Identifies the redispatch call across notifications. See Activations in each market for the identifier each market uses.

Example:

"b5a2c3e4-1f6d-4c8a-9e0b-7d3f2a1c5e68"

in_force
boolean
required

Whether this value is in force for this redispatch call at the time of the query. See Activations in each market for the rules that determine which values remain in force.

interval_from
string<date-time>
required

The inclusive start of the reported interval, as an ISO 8601 timestamp in UTC.

Example:

"2026-03-10T09:00:00Z"

interval_to
string<date-time>
required

The exclusive end of the reported interval, as an ISO 8601 timestamp in UTC.

Example:

"2026-03-10T09:15:00Z"

known_at
string<date-time>
required

When Engrate received the market message that holds the record, as an ISO 8601 timestamp in UTC. Use it to prevent look-ahead bias when you fit models: leave out the records that Engrate received after the time your model runs.

power_mw
number
required

The magnitude of the change in active power requested by the grid operator for this interval, in MW. The value is zero or positive. regulation_direction gives the direction of the change.

Example:

2.5

product
string
required

The activation product. redispatch means a grid operator requested a change in injection or withdrawal to manage a network constraint.

Allowed value: "redispatch"
regulation_direction
enum<string>
required

The direction of the call. up asks for more net injection: more production or less consumption. down asks for less net injection: less production or more consumption.

Available options:
up,
down
Example:

"down"

sender
string
required

The party code of the sender, as the notification gives it.

Example:

"8716867111187"

stated_at
string<date-time>
required

The market's timestamp used to version this value, as an ISO 8601 timestamp in UTC.

supplier
string
required

The party code of the accounting point’s supplier, as the notification gives it.

Example:

"8712423010208"