Skip to main content
On a normal day, your series match from the start. Then the trader changes a trade in the afternoon and you send a second revision with the same change. This page gives the values to send and the match state that you see after each revision. Test schedule matching tells you how the matching works in the test environment.

The plan of the day

The plan follows the times of the real market, in Amsterdam time on the day before delivery. The test environment does not wait for these times. When you send a revision, it moves the clock forward to your next place and sends you all the answers up to that place within a few minutes. Thus you can send your revisions at any time of the day, and the deadline does not apply.

What to send

Send all six series in each revision, also the series with 0 MW in every quarter-hour. Values are in MW for each quarter-hour, and the times are Amsterdam time. Send revision 1 with Create Schedule first. When its answers have come in, send revision 2, which changes only one thing: from 15:00 to 18:00 you sell 6 MW to the trader instead of 4 MW. If you already sent a revision for this delivery day, your next revision takes the place of revision 2. In that case, send revision 2 directly or start again with a new delivery day. A request for revision 1 starts like this:
ts is in UTC, so the delivery day starts at 23:00 UTC in winter and at 22:00 UTC in summer. Each series has a value for every quarter-hour of the day. That is 96 values on most days, 92 on the day when summer time starts and 100 on the day when it ends.

Match state after each revision

1

Revision 1

The match state of your series changes two times:The findings of the inconsistent series show your 4 MW against the trader’s 6 MW at positions 60 to 71, which is 15:00 to 18:00 on a day without a clock change. The other five series stay matched.
2

Revision 2

The market matches revision 2 and all six series are matched again. The scenario ends here.

Why two revisions

The Scheduling Area Responsible does not ask for two revisions. The scenario tests a common case in the real market: a counterparty changes a trade after the first confirmation and you send a new revision to match it. Because the trader’s change comes between your two places, no single revision matches the whole day. With 4 MW from 15:00 to 18:00, your series match until the trader’s change. With 6 MW, they do not match until after it.